Fridge Compressor Not Working – Common Faults Summary
| Fault/Symptom | Possible Cause | Diagnosis Method | Remedy |
|---|---|---|---|
| No Sound at All | Power supply issue | Check outlet with another device; verify breaker hasn’t tripped | Reset breaker; test outlet; check power cord |
| Clicking Sound Only | Failed start relay | Listen for repeated clicking every few minutes | Replace start relay |
| Clicking Sound Only | Faulty start capacitor | Test capacitor with multimeter for proper capacitance | Replace start capacitor |
| Humming Without Starting | Seized compressor | Listen for humming that stops after a few seconds; check if compressor is hot | Compressor replacement required |
| Compressor Hot to Touch | Overload protector tripped | Feel compressor temperature; wait 30 minutes and retry | Allow cooling; clean condenser coils |
| Compressor Overheating | Dirty condenser coils | Visual inspection of coils; check for dust/debris buildup | Clean condenser coils thoroughly |
| No Power to Compressor | Faulty thermostat | Test thermostat continuity with multimeter | Replace thermostat |
| No Power to Compressor | Defective control board | Check for error codes; test board connections | Replace electronic control board |
| Intermittent Operation | Loose electrical connections | Inspect all wire connections to compressor and relay | Tighten or repair connections |
| Won’t Start After Power Outage | Overload protector needs reset | Wait 5-10 minutes; check if compressor restarts | Allow reset time; may need manual reset |
| Runs Briefly Then Stops | Low refrigerant level | Check for frost on suction line; hissing sounds | Locate leak; repair and recharge system |
| Runs Briefly Then Stops | Faulty overload protector | Test protector with multimeter for continuity | Replace overload protector |
| Compressor Won’t Engage | Defrost timer stuck | Manually advance timer to see if compressor starts | Replace defrost timer |
| Starting Problems in Cold Environment | Low ambient temperature | Check location temperature (below 10°C problematic) | Move to warmer location or install heater kit |
| Electrical Burning Smell | Failed compressor windings | Smell near compressor; test windings with multimeter | Compressor replacement required |
| Frequent Tripping of Breaker | Compressor short circuit | Circuit breaker trips when refrigerator plugs in | Replace compressor; check wiring |
| No Response to Temperature Changes | Control board failure | Digital display frozen or unresponsive | Replace electronic control board |
| Compressor Cycles Too Frequently | Refrigerant overcharge | Check for excessive frost; abnormal pressure | Evacuate and recharge with correct amount |
| Grinding Noise Before Stopping | Internal compressor damage | Listen for metal-on-metal grinding sounds | Compressor replacement required |
| Vibration Without Starting | Compressor mounting failure | Check compressor mounts for looseness or damage | Replace compressor mounts; secure unit |
Important Notes:
Professional Diagnosis Required:
- Many compressor issues require specialized tools (multimeters, pressure gauges, refrigerant leak detectors)
- Refrigerant handling requires certification and proper environmental compliance
- Electrical testing should be performed with proper safety precautions
When to Call Refitec.co.ke:
- Any issue involving refrigerant system
- Compressor replacement needed
- Electrical component failures
- Persistent problems after basic troubleshooting
- Safety concerns with electrical systems
Safety Warning:
- Always unplug refrigerator before inspecting components
- Never attempt to repair a sealed refrigerant system without proper certification
- Compressors can remain hot for extended periods – allow cooling time
- High voltage components present – exercise caution